Fire Sprinkler Calculation Software Free Download

Features • Performs hydraulic calculations following NFPA 13 • Handles sprinkler systems with up to 1,000 sprinklers • Works on trees, grids, and hybrid sprinkler systems • Uses English or metric units • Tree Grid Pipe Network Builder included • Program runs in 32-bit and 64-bit Windows systems. • Computes flow rates, velocities, & pressure drops • Automatically sizes pipe • Analyzes stand pipe systems • Prints supply/demand graph on screen & printer • Allows for all types of pipe materials • Automatically calculates fitting equivalent lengths • Provides comprehensive NFPA style, high quality color presentation reports. Overview Elite's Fire Program quickly performs all necessary hydraulic calculations as required by the National Fire Protection Association (NFPA 13). Fire also estimates sprinkler head requirements, calculates optimal pipe sizes, and automatically performs a peaking analysis.

Powerful and affordable hydraulic calculation software for automatic fire sprinkler systems. Hydraulic calculation software for automatic fire sprinkler systems. Hottest apps with Download.

Fire can handle all types of sprinkler systems (trees, grids, and hybrids) with up to 1,000 or more sprinklers and pipes. Meters and standpipes can also be analyzed. Fire calculates the GPM water flow and velocity through all pipe sections, the GPM flow and residual pressure at each sprinkler head, the pressure losses incurred in each pipe section due to both friction and elevation changes, the maximum system demand pressure, and the total water GPM demanded by the system. The report format is designed to aid both the designer and the plan reviewer. Calculation Method Fire uses the Newton Raphson matrix solution technique to solve pipe networks, where each pipe is defined to flow according to the Hazen Williams formula. Calculations can be made for a given water supply pressure or they can be performed such that Fire determines the lowest water supply pressure that adequately drive the sprinkler system. Calculations are very fast and accurate.

The user manual lists all the pertinent equations to allow full manual verification. Program Input All input is checked at the time of entry so that no improper data can be entered. Upon completion of the input process, all data is saved and can be reviewed and edited whenever desired.

Two types of data are requested: general project data and pipe segment data. The general project data includes the project name and location, the client name, sprinkler specifications, hazard description, density requirements, hose stream allowances, hydrant test data, and other such data. The pipe data requires that each pipe section be defined as having a beginning and ending node number. If sprinkler heads are located at the pipe nodes, then the sprinkler K-factor must be given. In addition, the pipe length, nominal size, material type, and fitting quantities and types must be entered for each pipe section. Fire contains a built-in library of pipe materials that includes cast iron, copper, steel, PVC, and many others.

The pipe library allows up to 50 user defined pipe materials. Fitting equivalent lengths are automatically looked up depending upon fitting type, size, and pipe material. Free download super street fighter 4 pc game full version. Program Output The Fire Program provides numerous reports including: general project data, pipe and node input data, node grouping flows, detailed pipe and sprinkler output, supply/demand graph, and a network summary. You can specify exactly which reports are to be printed, and all reports can be previewed on the screen. Are just some of the available reports.

Free Update Fire now has the capability to handle a fire pump at or near the inflow point of the the system. Fire also can calculate using metric units.

Fire Sprinkler Calculation Software Free Download

These are highly significant and useful new features for Fire. This is a for existing users of Fire version 6.

Powerful and affordable hydraulic calculation software for automatic fire sprinkler systems. SHC has all the features you need to enter system data, evaluate results, and produce professional hydraulic calculation reports. Calculations use the Hazen-Williams or Darcy-Weisbach friction loss formula. Wet, dry, preaction, tree, loop, gridded, and custom systems may all be calculated. Multiple water sources, multiple booster pumps, multiple fixed loss devices, negative elevations, SI and U.S.

Units, automatic peaking, and velocity pressures are all supported. You may also create custom pipe diameters, fitting equivalent lengths, and liquid properties. SHC's modern syntax highlighting editor allows you to enter sprinkler system data efficiently with input flexibility most programs lack. Errors are highlighted in real time.

There are 'Pop-up helpers' for material and fitting codes so you don't have to memorize them. Automatic 'proposals' anticipate the next parameter and type it for you. Users may enter lengths and elevations using the foot and inch symbols. Group editing makes it easy to change all values of a specific type in your selection, such as k-factors or discharges. SHC even allows pipe and node names up to 8 alphanumeric characters long. SHC's calculation results window allows you to quickly evaluate your design.